Online
STRUCTURE SEALING

Structural Sealant and Seal Restoration

General structural sealing, sealant-removal and seal-restoration principles.

Key reference points

  • Sealant selection depends on environment and compatibility.
  • Removal tools must not damage the structure.
  • Preserve designed drainage and ventilation paths.

Organised training notes

1Match sealant to the application

Fluid exposure, temperature, pressure, material compatibility and cure conditions influence the approved sealant system.

2Restore disturbed faying seals

Panel or repair-part removal can break a faying-surface seal. Reinstallation may require complete seal restoration.

3Use non-damaging removal tools

Remove cured sealant with approved tools and methods that do not scratch, gouge or contaminate metal or composite surfaces.

4Keep drains and vents open

Do not block designed drain holes, vent paths or other openings while sealing a repair.

5Inspect before resealing

After removal, inspect for scratches, scribe marks, corrosion and other damage before surface preparation and resealing.

Training-reference boundary

This summary is not approved repair or maintenance data. Do not inspect, classify, select material, alter structure or perform a repair from this page alone. Use the current applicable SRM, AMM, engineering order, drawing and company procedures.